Uploaded image for project: 'JDK'
  1. JDK
  2. JDK-6308685

wrong debug info for FP values on sparc

XMLWordPrintable

    • Icon: Bug Bug
    • Resolution: Fixed
    • Icon: P3 P3
    • 6
    • 6
    • hotspot
    • None
    • b28
    • 6
    • b49
    • sparc
    • solaris_9

      The unification of OptoReg numbering missed the case for float registers on sparc, resulting in incorrect debug info. This would either cause wrong execution or a core dump because of a NULL location returned for an unsaved register.