Bug
-
Resolution: Fixed
-
P2
-
6u5
In the pipeline we assume that the numeration of the d3d
adapters is the same as GDI monitors. This may not be the case
if the user changed the primary display in the control panel.
This happens quite often on notebooks which are connected to
external monitors - the external monitor often becomes the
primary.
The result of this is that the pipeline could create surfaces
on wrong devices. Also, a full-screen window may appear on
the wrong screen (since wrong device will enter the FS mode).
adapters is the same as GDI monitors. This may not be the case
if the user changed the primary display in the control panel.
This happens quite often on notebooks which are connected to
external monitors - the external monitor often becomes the
primary.
The result of this is that the pipeline could create surfaces
on wrong devices. Also, a full-screen window may appear on
the wrong screen (since wrong device will enter the FS mode).